Smoke Cue Model
Short description of suggestion
- User defines a pre-movement time (e.g. 120 s)
-
- detection time (e.g. 60s)
That means: the occupant remains in that position for 180 s regardless the occurrence of smoke or temperature.
It would be good if we can implement a function in the model that changes the pre-movement time of the occupant to 0 when the visibility drops to 10 m.
Why would the enhancement be useful to most users
In this way, no weird results are obtained regarding people waiting in the smoke